BioSampler

  • Allows use of non-evaporating collection liquids
  • Patented swirling liquid collection method minimises re-aerosolisation and particle bounce
  • Preserves micro-organism integrity and viability
  • Reusable — can be autoclaved
  • Maintains constant sampling efficiency up to 8 hours
  • Collected bioaerosols can be analysed by a variety of methods
  • Complete glass construction allows easy cleaning, sterilising, autoclaving and reuse
  • Collection liquid easily ransferred to agar plate for culturing
SKU: 225-9595 Category:

Description

While there is no standardised method for bioaerosol collection at this time, many organisations, including SKC, are researching improved measurement techniques. The patented BioSampler® is a result of SKC’s work with leading scientists at the University of Cincinnati.

BioSampler Operation

The BioSampler® must be operated with a high volume sonic flow pump, such as the BioLite/BioLite+ Pump, that can maintain 15 inches mercury or 0.5 of an atmosphere of downstream pressure in the system. The BioSampler’s three tangential nozzles act as critical (sonic) orifices, each permitting 4.2 L/min of ambient air to pass through for a total flow rate of approximately 12.5 L/min. Collection liquid with a viscosity much higher than water, such as ViaTrap (special mineral oil), can be used with the BioSampler to provide constant collection efficiency over an 8 hour sampling period.

Applications

  • Indoor air quality investigations
  • Infection control in hospitals and veterinary clinics
  • Quantification of microorganisms in agricultural dust
  • Biological research
  • Infectious disease investigations in public buildings
  • Safety concerns in the food handling industry
  • Workplace exposures in industries such as pulp and paper mills or wastewater treatment plants

SPECIFICATIONS

Sample Time Up to 8 hours
Sample Rate Sonic flow through BioSampler nozzles (12.5 L/min)
Sample Pump BioLite/BioLite+ Pump
Sample Media Water or more viscous liquids such as ViaTrap mineral oil
Tubing 1/4 inch ID and 3/8 inch ID

ANALYSIS OPTIONS

BioSampler samples provide many analysis options:

  • Growth Culture Analysis quantifies and characterises airborne cultural bacteria and fungi
  • Microscopic Analysis enumerates and provides limited identification of total airborne bacteria and fungi
  • Biochemical Assay quantifies biological compounds based on reaction to a chemical
  • Immunoassay quantifies airborne allergens based on antibodies binding to a specific target antigen
  • Polymerase 

BIO SAMPLERS

Description Part Number
20 ml BioSampler (Single), 3-piece glass, includes: 225-9595
inlet section, outlet section, and collection vessel (does not include ground joint cap). Inlet and outlet sections are a matched set
20 ml BioSampler (Set of 4), 3-piece glass, includes: 225-9595K4
inlet section, outlet section, and collection vessel (does not include ground joint cap). Inlet and outlet sections are a matched set
5 ml BioSampler, 3-piece glass, includes: 225-9593
inlet section, outlet section, and collection vessel (does not include ground joint cap). Inlet and outlet sections are a matched set

BIO SAMPLER KITS

KITS
Description Part Number
BioSampler Mini Kit includes: 225-9597
BioSampler, two 20 ml collection vessels (bottoms) with caps, 1 BioSampler case with mounting rod, and 1 ViaTrap (120 ml).
Viatrap mineral oil may not be suitable for PCR analysis
BioLite+ BioSampler Kit 230V includes: 228-9620KB
BioLite+ 230V pump, 1 BioSampler, vessel, cap, and one additional 20 ml collection vessel with cap, 1 mounting bracket, tubing/adapters and rotameter
BioLite+ BioSampler Deluxe Kit 230V includes: 228-9620KBD
BioLite+ 230V pump, 1 BioSampler, two 20 ml collection vessels with caps, 1 case with mounting rod, 1 ViaTrap* (120 ml), tubing/adapters and rotameter
BioLite+ BioSampler Kit 120V includes: 228-9615KB
BioLite+ 120V pump, 1 BioSampler, vessel, cap, and one additional 20 ml collection vessel with cap, 1 mounting bracket, tubing/adapters and rotameter
BioLite+ BioSampler Deluxe Kit 120V includes: 228-9615KBD
BioLite+ 120V pump, 1 BioSampler, two 20 ml collection vessels with caps, 1 case with mounting rod, 1 ViaTrap* (120 ml), tubing/adapters and rotameter

ACCESSORIES

Description Part Number
20 ml BioSampler Collection Vessel (bottom) and ground joint cap, for transporting samples 225-9596
5 ml BioSampler Collection Vessel (bottom) and ground joint cap, for transporting samples 225-9596A
120 ml ViaTrap Collection Media, special mineral oil for bioaerosol sampling. 225-9598A
Viatrap mineral oil may not be suitable for PCR analysis
500 ml ViaTrap Collection Media, special mineral oil for bioaerosol sampling. 225-9598
Viatrap mineral oil may not be suitable for PCR analysis
950 ml ViaTrap Collection Media, special mineral oil for bioaerosol sampling. 225-9599
Viatrap mineral oil may not be suitable for PCR analysis
BioSampler Case with Mounting Rod, includes foam insert. Case serves as a base and rod secures BioSampler during sampling 225-9606
Glass Trap for area sampling to protect pump and can be used with or without trap sorbent 225-22
Trap Sorbent 200 g, silica gel/activated charcoal mix to remove vapours 225-22-02
BioSampler Mounting Bracket for BioLite+/BioLite Pump 228-9611

DOCUMENTS

Bio-Sampler Instructions
Bio Sampler Brochure