SKC QuickTake 30 Pump

  • Ideal for sampling biological hazards (fungal spore or bacteria)
  • High flow rate which built-in back pressure gauge
  • Robust metal casing with integral handle
  • Works in conjunction with a BioSampler
  • Two mounting points allows two BioSamplers to be attached and operated simultaneously at a total flow rate of 25 L/min
  • Simple flow adjustment

 

The QuickTake 30 air sampling pump is not UL Listed for intrinsic safety.

SKU: 228-9530 Category:

Description

The QuickTake® 30 air sampling pump offers constant flows from 10 to 30 L/min and run times up to 14 hours for sampling particulates. The pump is ideal for use with impactors, microvacuum cassettes, and spore traps.

Attributes

  • Pump Flow Rate :10 to 30 L/min
  • PC Compatible :No
  • Programable :No
  • Intrinsic Safety :No
  • Battery Type (Power) :Li-Ion
  • Approx Run Time :14 hours
  • Constant Flow :Yes

Specifications

Flow Range 10 to 30 L/min
Flow Compensation Accuracy ± 5% of set flow
Compensating Flow Back Pressure Range 10 L/min at 90 inches water back pressure
20 L/min at 50 inches water back pressure
30 L/min at 15 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate L/min 10 12 15 20
Filter/Pore Size (µm)
25-mm MCE/0.8 65 80 103 148
25-mm MCE/0.45 138 172 > 200
37-mm MCE/0.8 22 28 36 51
37-mm PVC/5.0 9 11 15 21
Compare the information in this table to compensation range to determine appropriate applications.
Power Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 77 Wh, or battery with AC charger/adapter (100-240 V)
Battery Recharge Time Approximately 5 hrs with approved charger
(varies with battery capacity and level of discharge)
Typical Cumulative Run Time‡ Spore Trap cassettes (VersaTrap): 5 hrs at 15 L/min (battery only)
BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only)
25-mm, 1.2-µm MCE filter: 9+ hrs at 10 L/min
To achieve, use QuickTake 30 with a fully charged battery and AC charger/adapter.
37-mm, 0.8-µm MCE filter: 14+ hrs at 10 L/min (battery only)
Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times.
Temperature Operating: 32 to 104 F (0 to 40 C)
Storage: -4 to 95 F (-20 to 35 C)
Charging: 32 to 113 F (0 to 45 C)
Operating Humidity 0 to 95% non-condensing
Run Time Features User-selectable features, user-adjustable presets. See Operating Instructions.
Preset timed runs: 1, 2, 5, 10, or 15 min
Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted)
Intermittent sampling: User-set sample periods and sample delays. See Operating Instructions.
Flow Fault Features If the pump is unable to compensate due to excessive back pressure, the pump will go into flow fault mode. Flow fault features are enabled as the default setting. Flow fault may be disabled at the user’s option. See Operating Instructions.
Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds.
Fault restart: Pump attempts restart every 10 seconds up to five times.
Media Compatibility BioStage viable cascade impactor, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min
Tubing Requires 3/8-inch ID tubing
Housing ABS plastic
Dimensions 8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm)
Weight 4.8 lbs (2.2 kg)
Noise Level Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min)

Documents

QuickTake30 – Catalog
QuickTake30 – Examination Certificate
QuickTake30 – Operating Instructions
QuickTake30 – Sample Pump
QuickTake30 – Tech Notes