SKC QuickTake 30 Pump
- Ideal for sampling biological hazards (fungal spore or bacteria)
- High flow rate which built-in back pressure gauge
- Robust metal casing with integral handle
- Works in conjunction with a BioSampler
- Two mounting points allows two BioSamplers to be attached and operated simultaneously at a total flow rate of 25 L/min
- Simple flow adjustment
The QuickTake 30 air sampling pump is not UL Listed for intrinsic safety.
Description
The QuickTake® 30 air sampling pump offers constant flows from 10 to 30 L/min and run times up to 14 hours for sampling particulates. The pump is ideal for use with impactors, microvacuum cassettes, and spore traps.
Attributes
- Pump Flow Rate :10 to 30 L/min
- PC Compatible :No
- Programable :No
- Intrinsic Safety :No
- Battery Type (Power) :Li-Ion
- Approx Run Time :14 hours
- Constant Flow :Yes
Specifications
Flow Range | 10 to 30 L/min | |||
Flow Compensation Accuracy | ± 5% of set flow | |||
Compensating Flow Back Pressure Range | 10 L/min at 90 inches water back pressure | |||
20 L/min at 50 inches water back pressure | ||||
30 L/min at 15 inches water back pressure | ||||
Typical Back Pressure of Sampling Media (inches water) | ||||
Flow Rate L/min | 10 | 12 | 15 | 20 |
Filter/Pore Size (µm) | ||||
25-mm MCE/0.8 | 65 | 80 | 103 | 148 |
25-mm MCE/0.45 | 138 | 172 | > 200 | — |
37-mm MCE/0.8 | 22 | 28 | 36 | 51 |
37-mm PVC/5.0 | 9 | 11 | 15 | 21 |
Compare the information in this table to compensation range to determine appropriate applications. | ||||
Power | Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 77 Wh, or battery with AC charger/adapter (100-240 V) | |||
Battery Recharge Time | Approximately 5 hrs with approved charger | |||
(varies with battery capacity and level of discharge) | ||||
Typical Cumulative Run Time‡ | Spore Trap cassettes (VersaTrap): 5 hrs at 15 L/min (battery only) | |||
BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only) | ||||
25-mm, 1.2-µm MCE filter: 9+ hrs at 10 L/min | ||||
To achieve, use QuickTake 30 with a fully charged battery and AC charger/adapter. | ||||
37-mm, 0.8-µm MCE filter: 14+ hrs at 10 L/min (battery only) | ||||
Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times. | ||||
Temperature | Operating: 32 to 104 F (0 to 40 C) | |||
Storage: -4 to 95 F (-20 to 35 C) | ||||
Charging: 32 to 113 F (0 to 45 C) | ||||
Operating Humidity | 0 to 95% non-condensing | |||
Run Time Features | User-selectable features, user-adjustable presets. See Operating Instructions. | |||
Preset timed runs: 1, 2, 5, 10, or 15 min | ||||
Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted) | ||||
Intermittent sampling: User-set sample periods and sample delays. See Operating Instructions. | ||||
Flow Fault Features | If the pump is unable to compensate due to excessive back pressure, the pump will go into flow fault mode. Flow fault features are enabled as the default setting. Flow fault may be disabled at the user’s option. See Operating Instructions. | |||
Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds. | ||||
Fault restart: Pump attempts restart every 10 seconds up to five times. | ||||
Media Compatibility | BioStage viable cascade impactor, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min | |||
Tubing | Requires 3/8-inch ID tubing | |||
Housing | ABS plastic | |||
Dimensions | 8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm) | |||
Weight | 4.8 lbs (2.2 kg) | |||
Noise Level | Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min) |